£76.88

Manual Fire Alarm Call Point With Backbox and Isolator Red

The Intelligent Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the Control and Indicating Equipment using an interrupt feature within the Digital Protocol. An alarm status is indicated through the rotation of the resettable element, displaying yellow and black indication bars and a solid red LED. The manual call point can be easily reset from the front using the supplied reset key.

The Intelligent Manual Call Point will operate with compatible control equipment using the digital XP95, Discovery and Core Protocols.

Product Specification

  • Resettable operating element
  • Easy access, front reset mechanism
  • E-Z fit connector system for installation
  • EN 54-11 & EN 54-17 Certified (Red version only)
  • 170° viewable LED
  • Continuity link for cable insulation testing
  • Suitable for semi flush or surface mounting

Technical Specification

  • Supply voltage 17-35V DC
  • Digital Communications Protocol        CoreProtocol , Discovery & XP95 compatible 5-13V Peak to Peak
  • Current Consumption (max) at 24V
  • DC Power Up Surge (1s typical) 1mA
  • Quiescent 100µA Alarm current (LED On) 4mA
  • Operating temperature -40°C to 70°C
  • Humidity 0% to 95%RH (no condensation or icing)
  • Vibration, impact and shock EN 54-11 & EN 54-17 (Red version only)
  • IP Rating IP44
  • Approvals & standards EN 54-11, EN 54-17, CPR & LPCB (Red version only)
  • Dimensions 90mm height x 90mm width x 63mm depth
  • Weight 180g

Operating Principles

The address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point, by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and Core-Protocol configurable. Once activated, the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED, turning clockwise until a positive click and reset occurs. The Intelligent Manual Call Point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a solid yellow LED. This manual call point helps reduce installation time as all the initial installation cabling is wired to a removable terminal block which fits neatly in the back of the manual call point.

Read more...

FREE
SHIPPING

100% MONEY
BACK GUARANTEE

ONLINE
SUPPORT 24/7

Sku: AB127-1054

Manual Fire Alarm Call Point With Backbox and Isolator Red

The Intelligent Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the Control and Indicating Equipment using an interrupt feature within the Digital Protocol. An alarm status is indicated through the rotation of the resettable element, displaying yellow and black indication bars and a solid red LED. The manual call point can be easily reset from the front using the supplied reset key.

The Intelligent Manual Call Point will operate with compatible control equipment using the digital XP95, Discovery and Core Protocols.

Product Specification

  • Resettable operating element
  • Easy access, front reset mechanism
  • E-Z fit connector system for installation
  • EN 54-11 & EN 54-17 Certified (Red version only)
  • 170° viewable LED
  • Continuity link for cable insulation testing
  • Suitable for semi flush or surface mounting

Technical Specification

  • Supply voltage 17-35V DC
  • Digital Communications Protocol        CoreProtocol , Discovery & XP95 compatible 5-13V Peak to Peak
  • Current Consumption (max) at 24V
  • DC Power Up Surge (1s typical) 1mA
  • Quiescent 100µA Alarm current (LED On) 4mA
  • Operating temperature -40°C to 70°C
  • Humidity 0% to 95%RH (no condensation or icing)
  • Vibration, impact and shock EN 54-11 & EN 54-17 (Red version only)
  • IP Rating IP44
  • Approvals & standards EN 54-11, EN 54-17, CPR & LPCB (Red version only)
  • Dimensions 90mm height x 90mm width x 63mm depth
  • Weight 180g

Operating Principles

The address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point, by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and Core-Protocol configurable. Once activated, the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED, turning clockwise until a positive click and reset occurs. The Intelligent Manual Call Point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a solid yellow LED. This manual call point helps reduce installation time as all the initial installation cabling is wired to a removable terminal block which fits neatly in the back of the manual call point.

Delivery Policy
Delivery dates are quoted subject to the availability of product. Every effort will be made to effect delivery within the quoted period, but no liability can be accepted should it be exceeded. Customers from outside the UK should contact us for shipping quote before making purchase.
Purchasing Goods
To purchase from us you must be over 18. We accept credit/debit card payments.We can ship worldwide. We accept credit cards from the UK& USA only. Other countries are by bank transfer only. Please contact us for further details.
Buying online
Just browse our store and add any items you wish to purchase to the shopping basket. When you have finished, click on the basket/checkout to complete your transaction. All transactions placed online are made through an encrypted service. If you discover you have made a mistake with your order please contact us immediately. All prices and offers are subject to change and availability.